Inquiry For Liaison Service
Sector abcEducation And Research InstituteTender Value 1.50 Crore
LocationRajasthan - India Ref.No70209447
Closing Date13 - May - 2024
Supply of Disposable Surgical and Chemicals Used in Dialysis Dept.-"dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Effective Surface Area 1.1 Sqm, dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Effective Surface Area 1.3 Sqm, dialyzer with Blood Tubing Set , Dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Blood Tubing Set Must Be Same Company of Dialyzer, Effective Surface Area 1.4 Sqm, dialyzer with Blood Tubing Set , Dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Blood Tubing Set Must Be Same Company of Dialyzer, Effective Surface Area 1.5 Sqm, dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Effective Surface Area 1.6 Sqm , dialyzer with Blood Tubing Set , Dialyzer Should Be Synthetic Membrane(polysulfone Or Poly Ethersulfone), Blood Tubing Set Must Be Same Company of Dialyzer, Effective Surface Area 1.8 Sqm, pediatric Dialyzer with Pediatric Blood Tubing , Dialyzer Should Be Synthetic Membrane(as Polysulfone Or Poly Ethersulfone), Effective Surface Area 0.6 Sqm, pediatric Dialyzer with Pediatric Blood Tubing , Dialyzer Should Be Synthetic Membrane(as Polysulfone Or Poly Ethersulfone), Effective Surface Area 0.8 Sqm, double Lumen Catheter with Kit Curved/ Straight Catheter Should Be Made of Flexible Radio Opaque Polyurethane with a Radio Opaque Tip (easy Visualization in X Ray), Accessory Shuold Be Provided as Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire with Dispenser and Inj. Caps), Catheter Should Be Usfda Approved (certificate Must Be Enclosed.), Size 11.5/12 Fr X 13 Cm, double Lumen Catheter with Kit Internal Jugular Curved/ Straight Catheter Should Be Made of Flexible Radio Opaque Polyurethane with a Radio Opaque Tip (easy Visualization in X Ray), Accessory Shuold Be Provided as Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire with Dispenser and Inj. Caps), Catheter Should Have Usfda Approved (certificate Must Be Enclosed.), Size 8.5/09 Fr X 11 Cm, double Lumen Catheter with Kit Internal Jugular Curved/ Straight Catheter Should Be Made of Flexible Radio Opaque Polyurethane with a Radio Opaque Tip (easy Visualization in X Ray), Accessory Shuold Be Provided as Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire with Dispenser and Inj. Caps), Catheter Should Have Usfda Approved (certificate Must Be Enclosed.), Size 10 Fr X 12 Cm, double Lumen Catheter with Kit Internal Jugular Curved/ Straight Catheter Should Be Made of Flexible Radio Opaque Polyurethane with a Radio Opaque Tip (easy Visualization in X Ray), Accessory Shuold Be Provided as Contains( Catheter, Dilator, Introducer Needle Syringe, Guide Wire with Dispenser and Inj. Caps), Catheter Should Have Usfda Approved (certificate Must Be Enclosed.), Size 11.5 X 12 Fr X 16/15 Cm, disposable Biopsy Gun Needle Automated Spring Loaded Presterile Size 16g/18g-, Needle Should Be Us Fda Approved (certificate Must Be Enclosed), It Should Have Sample Notch Size 1.8 Cm and 1.9 Cm.it Should Have Non Roll Handle Design., ", A.v Fistula Needle 16g Rotating Wing Tuype Having Back Eye, A.v Fistula Needle 17g Rotating Wing Tuype Having Back Eye, Haemo Dialysis Solution Fluid Concentrate (part A) 10 Ltr with Bicarbonate Powder 2 Pkt(part-b), H.d Fluid High Concentrate Part a Compatible with Bibag- Company Must Be Iso and Gmp Certified (certificate Must Be Enclosed), "hot Sterlilzation Solution 5 Ltr Jar, Solution Should Be Effective for Cleaning Bil Film Calcium Magnesium Deposited to Reduce Haemo Dialysis Machine Breakdown and Use for Machine Disinfection, sodium Hypochlorite Soloution-, concentrate in 5ltr Can, acetic- Acid Soloution-, concentrate in 5ltr Can, hydrochloric Acid Solution-, concentrate in 5ltr Can, citrosteril Solution-, concentrate in 5ltr Can, high Flux Dialyzer -, Effective Surface Area - 0.9 M2, Specification -, 1. Dialyzer Should Be of a Reputed International Make-, 2. Must Be European Ce From a Notified Body/ Usfda Certified (certificate Must Be Enclosed), 3. Inside Diameter of Fiber Should Be 200 Micro Meter., 4. It Should Using the Sterilization Method of Steam/gamma., high Flux Dialyzer -, Effective Surface Area - 1.1 M2, Specification -, 1. Dialyzer Should Be of a Reputed International Make-, 2. Must Be European Ce From a Notified Body/ Usfda Certified (certificate Must Be Enclosed), 3. Inside Diameter of Fiber Should Be 200 Micro Meter., 4. It Should Using the Sterilization Method of Steam/gamma, high Flux Dialyzer -, Effective Surface Area - 1.4 M2, Specification -, 1. Dialyzer Should Be of a Reputed International Make-, 2. Must Be European Ce From a Notified Body/ Usfda Certified (certificate Must Be Enclosed), 3. Inside Diameter of Fiber Should Be 200 Micro Meter., 4. It Should Using the Sterilization Method of Steam/gamma, high Flux Dialyzer -, Effective Surface Area - 1.5 M2, Specification -, 1. Dialyzer Should Be of a Reputed Internation
If you are a new user, then please register, it's Free and then fill the form below.

If you are registered with us, just fill the form below, we will get back to you shortly.


All fileds marked with '*' are compulsary.
Email Id : *
Comments: *
 Login/Register
Members/Visitors Login to continue
 Email Id:
 Password:


 Forgot Password?
 Tenders by Ownership
Central Government/Public Sector Tenders
Co-operatives Tenders
Corporations/ Associations/ Others Tenders
Education & Research Institutes Tenders
Joint Sector Tenders
Non classified Tenders
Private Sector Tenders
Research Institutes Tenders
State Government Tenders
Trust Tenders